Mã sản phẩm:
MP25A to 7400A Two or four quadrant operation (regenerative)
24V - 480V / 500V - 575V / 500V - 690V
Mentor MP brings DC drive technology up to date, enabling existing and new DC motors to provide economic and productive service. DC drive technology remains cost effective, efficient and is relatively simple to implement. For new applications DC drive provides many advantages, especially for regenerative and high power applications.
Features
Greater motor field control
Built in field controller as standard
Gives excellent field control for the majority of DC motors
Reduces the need for external components
Enhanced field control with FXMP25
The FXMP25 may be controlled digitally by using a standard RJ45 connection, allowing set-up by standard drive parameters
The FXMP25 can also function in standalone mode using its integrated keypad and display
Enhanced system design
The heatsink cooling fans are intelligently controlled and only run when required, thus increasing reliability and reducing maintenance
Eighteen different option modules allow customisation of the drive, including fieldbus, Ethernet, I/O, extra feedback devices and motion controllers
The drive system designer is able to embed automation and motion control within the drive, eliminating communications delays that reduce performance
Fast set-up, configuration and monitoring
Quick and easy to set-up
Can be configured using optional removable keypads
Advanced autotune features help you get the best performance from your machine
PC software and Smartcard tools for rapid commissioning
Intelligent networked system with CTNet
Program inbuilt controller with SyPTLite
Develop tailored solutions for applications modules with SyPTPro
Option modules for all common Industrial Ethernet, fieldbus networks
Retro-fit projects
Easy integration with your existing motor, power supply, application equipment and communication networks has been ensured from the design stage
Mentor MP brings performance and possibilities to your application with minimum migration costs
Ease of migration
Mentor MP has been designed so existing Mentor II customers can easily migrate to the new platform
All power terminal locations and mounting points have been retained
Mentor MP has a much smaller frame size than the 900 A Mentor II with paralleling options to offer high power density
CT Soft has a built in migration wizard to assist with the transfer of drive parameters and programs
Smaller cable requirements make connections within the cubical easier. Construction of a custom-made bus-bar is not required
Motor Field Control
Built in field controller as standard in every Mentor MP
An external motor field controller is recommended when:
The required field current is greater than that offered by the standard drive, up to 25 A. For example, older motors with low field voltages
The field is required to be forced down more quickly than is possible with a standard half controlled field bridge
Applications can be implemented with simple field current reversal, without armature reversal, if machine dynamics can still be met
QR code for Catalog:
Specifications
Models available for two or four quadrant (regenerative) operation
Current ratings
The power ratings for the 480V, 575V and 690V configurations are shown below.
The continuous current ratings given are for a maximum ambient temperature of 40°C (104°F) and an altitude of 1000m (3,300ft). For operation at higher temperatures and altitudes de-rating is required. Overload of 150% for 30s is available with ambient temperature of 40°C (104°F) up to a maximum of 10 repetitions per hour.
230V ratings
MODEL |
AC INPUT CURRENT |
DC OUTPUT CURRENT |
TYPICAL MOTOR POWER |
||
CONTINUOUS |
CONTINUOUS |
150% OVERLOAD |
240Vdc |
||
A |
A |
A |
hp |
||
MP25A4(R) |
22 |
25 |
37.5 |
5 |
|
MP45A4(R) |
40 |
45 |
67.5 |
10 |
|
MP75A4(R) |
67 |
75 |
112.5 |
20 |
|
MP105A4(R) |
94 |
105 |
157.5 |
30 |
|
MP155A4(R) |
139 |
155 |
232.5 |
40 |
|
MP210A4(R) |
188 |
210 |
315 |
60 |
|
MP350A4(R) |
313 |
350 |
525 |
100 |
|
MP420A4(R) |
376 |
420 |
630 |
125 |
|
MP550A4(R) |
492 |
550 |
825 |
150 |
|
MP700A4(R) |
626 |
700 |
1050 |
200 |
|
MP825A4(R) |
738 |
825 |
1237.5 |
225 |
|
MP900A4(R) |
805 |
900 |
1350 |
250 |
|
MP1200A4(R) |
1073 |
1200 |
1800 |
350 |
|
MP1850A4(R) |
1655 |
1850 |
2775 |
550 |
480V ratings
MODEL |
AC INPUT CURRENT |
DC OUTPUT CURRENT |
TYPICAL MOTOR POWER |
||
CONTINUOUS |
CONTINUOUS |
150% OVERLOAD |
@ 400 Vdc |
@ 500 Vdc |
|
A |
A |
A |
kW |
hp |
|
MP25A4(R) |
22 |
25 |
37.5 |
9 |
15 |
MP45A4(R) |
40 |
45 |
67.5 |
15 |
27 |
MP75A4(R) |
67 |
75 |
112.5 |
27 |
45 |
MP105A4(R) |
94 |
105 |
157.5 |
37.5 |
60 |
MP155A4(R) |
139 |
155 |
232.5 |
56 |
90 |
MP210A4(R) |
188 |
210 |
315 |
75 |
125 |
MP350A4(R) |
313 |
350 |
525 |
125 |
200 |
MP420A4(R) |
376 |
420 |
630 |
150 |
250 |
MP550A4(R) |
492 |
550 |
825 |
200 |
300 |
MP700A4(R) |
626 |
700 |
1050 |
250 |
400 |
MP825A4(R) |
738 |
825 |
1237.5 |
300 |
500 |
MP900A4(R) |
805 |
900 |
1350 |
340 |
550 |
MP1200A4(R) |
1073 |
1200 |
1800 |
450 |
750 |
MP1850A4(R) |
1655 |
1850 |
2775 |
700 |
1150 |
575V ratings
MODEL |
CURRENT |
DC OUTPUT CURRENT |
TYPICAL MOTOR POWER
|
||
CONTINUOUS |
CONTINUOUS |
150% OVERLOAD |
|
|
|
A |
A |
A |
kW |
hp |
|
MP25A5(R) |
22 |
25 |
37.5 |
14 |
15 |
MP45A5(R) |
40 |
45 |
67.5 |
25 |
30 |
MP75A5(R) |
67 |
75 |
112.5 |
42 |
50 |
MP105A5(R) |
94 |
105 |
157.5 |
58 |
75 |
MP155A5(R) |
139 |
155 |
232.5 |
88 |
100 |
MP210A5(R) |
188 |
210 |
315 |
120 |
150 |
MP350A5(R) |
313 |
350 |
525 |
195 |
250 |
MP470A5(R) |
420 |
470* |
705 |
265 |
350 |
MP700A5(R) |
626 |
700 |
1050 |
395 |
500 |
MP825A5(R) |
738 |
825* |
1237.5 |
465 |
600 |
MP1200A5(R) |
1073 |
1200 |
1800 |
680 |
900 |
MP1850A5(R) |
1655 |
1850 |
2775 |
1045 |
1400 |
*For this rating at 575V, 150% overload time is 20s at 40°C and 30s at 35°C
690V ratings
MODEL |
AC INPUT CURRENT |
DC OUTPUT CURRENT |
TYPICAL MOTOR POWER |
||
CONTINUOUS |
CONTINUOUS |
150% OVERLOAD |
@ 760 Vdc |
@ 700 Vdc |
|
A |
A |
A |
kW |
hp |
|
MP350A6(R) |
313 |
350 |
525 |
240 |
300 |
MP470A6(R) |
420 |
470* |
705 |
320 |
400 |
MP700A6(R) |
626 |
700 |
1050 |
480 |
600 |
MP825A6(R) |
738 |
825* |
1237.5 |
650 |
700 |
MP1200A6(R) |
1073 |
1200 |
1800 |
850 |
1000 |
MP1850A6(R) |
1655 |
1850 |
2775 |
1300 |
1600 |
* For this rating at 690V, 150% overload time is 20s at 40C ° and 30s at 35C °
Inputs and Outputs
FUNCTION |
QTY |
I/O DEFAULT FUNCTION |
RATING |
Analog input 1 |
1 |
Speed ref 1 |
10V± |
Analog input 2
|
1 |
Speed ref 2 |
10V(default), 0-20mA or 4-20mA± |
Analog input 3 |
1 |
Motor thermistor |
10V, 0-20mA, 4-20mA or Motor thermistor input (default)± |
Analog output |
2 |
Speed feedback output Current feedback output |
10V(default), 0-20mA or 4-20mA± |
Digital input |
3 |
Run reverse input Local/Remote select Jog forward input |
+24V |
Digital input / output |
3 |
At speed output Reset input Run forward input |
+24V |
Relay |
2 |
Drive OK indicator |
Normally closed |
Drive enable |
1 |
Drive enable |
+24V |
+24V External input |
1 |
External 24V supply |
+24V |
Conformance
Humidity 95% maximum (non condensing) at 40°C (104°F)
Ambient temperature -15°C to +40°C (5°F to +104°F), 55°C (131°F) with derating
Altitude: 0 to 3000m (9,900ft), derate 1% per 100m between 1000m (3,300ft) and 3000m (9,900ft)
Vibration: Tested in accordance with IEC 60068-2-64
Mechanical shock tested in accordance with IEC 60068-2-29
Storage temperature -40°C to +70°C (-40°F to +158°F)
Electromagnetic immunity complies with EN 61800-3 and EN 61000-6-2
Notch Immunity to IEC60146-1-1 class A
IEC 61800-5-1 Electrical safety
IEC 61131-2 I/O
EN 60529 Ingress protection
UL508C
EN 61000-6-4 EMC - with optional EMC filters
RoHS compliant
MODEL |
FRAME |
ARMATURE CURRENT (A)* |
FIELD CURRENT (A) |
OVERALL DIMENSION |
OPERATIONQUADRANTS OF |
||||
480V EN / IEC cULus
|
575V EN / IEC cULus to 600V |
690V EN / IEC |
(W) |
(H) |
Depth |
||||
MP25A4(R) |
MP25A5(R) |
|
1A
|
*25 |
8 |
293mm (11.54in) |
444mm (17.48in) |
222mm (8.74in)
|
2 and 4
|
MP45A4(R) |
MP45A5(R) |
|
*45 |
||||||
MP75A4(R) |
MP75A5(R) |
|
*75 |
||||||
MP105A4(R) |
MP105A5(R) |
|
1B |
*105 |
293mm (11.54in) |
444mm (17.48in) |
251mm (9.88in)
|
2 and 4
|
|
MP155A4(R) |
MP155A5(R) |
|
*155 |
||||||
MP210A4(R) |
MP210A5(R) |
|
*210 |
||||||
MP350A4(R) |
MP350A5(R) |
MP350A6(R) |
2A
|
*350 |
20 |
495mm (19.49in) |
640mm (25.20in) |
301mm (11.85in)
|
2 and 4
|
MP420A4(R) |
|
|
*420 |
||||||
|
MP470A5(R) |
MP470A6(R) |
470** |
||||||
MP550A4(R) |
|
|
*550 |
||||||
MP700A4(R) |
MP700A5(R) |
MP700A6(R) |
2B
|
*700 |
495mm (19.49in) |
640mm (25.20in) |
301mm (11.85in)
|
2 and 4
|
|
MP825A4(R) |
MP825A5(R) |
MP825A6(R) |
825** |
||||||
MP900A4(R) |
|
|
*900 |
||||||
MP1200A4 |
MP1200A5 |
MP1200A6 |
2C |
*1200 |
555mm (21.85in) |
1050mm *** |
611mm (24.06in) |
2
|
|
MP1850A4 |
MP1850A5 |
MP1850A6 |
*1850 |
||||||
MP1200A4R |
MP1200A5R |
MP1200A6R |
2D |
*1200 |
555mm (21.85in) |
1510mm (59.45in) *** |
611mm (24.06in) |
4 |
|
MP1850A4R |
MP1850A5R |
MP1850A6R |
1850* |
*Current ratings are at 40°C with 150% overload for 30s.
**For this rating at 575V and 690V, 150% overload time is 20s at 40°C and 30s at 35°C.
***Height including optional fit exhaust duct cover is 1252mm (49.29in) for size 2C and 1712mm (67.40in) for size 2D.
7400A is achieved by parallel connection of Mentor MP drives